IviACPwr Query Output Impedance Capabilities [IMP] VI
This VI queries the output impedance capabilities of the AC power source based on the present configuration.
instrument handle The instrument handle that you obtain from the IviACPwr Initialize or IviACPwr Initialize With Options VIs. The handle identifies a particular instrument session.
Default Value: None |
|
Phase Name ("") Specifies the name of the output phase to configure.
Pass the virtual output phase name that you assign to the instrument in the IVI Configuration utility. Virtual output phase names are aliases for instrument-specific output phase strings, which can differ from one instrument to another. With virtual output phase names, you can use and swap instruments without having to change the output phase names in your source code. Assign a virtual output phase name to an instrument-specific output phase through the IVI Configuration utility. This control accepts virtual output phase names you have assigned to the specific instrument you are using and also accepts the instrument-specific output phase names. Default Value: "" Note: You can specify the output phase name as a string variable or as a literal enclosed in double quotes. |
|
error in (no error) The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.
The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
Inductive Min Returns the minimum inductive impedance value the power source can be programmed. | |
instrument handle out The instrument handle that you obtain from the IviACPwr Initialize or IviACPwr Initialize With Options VIs. | |
Resistive Min Returns the minimum resistive impedance value the power source can be programmed. | |
Resistive Max Returns the maximum resistive impedance value the power source can be programmed. | |
error out The error out cluster passes error or warning information out of a VI to be used by other VIs.
The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
Inductive Max Returns the maximum inductive impedance value the power source can be programmed. |